Re: 97 GC - Blower comes on by itself -- with no key!!
PoBoy proclaimed:
> No the blower under the dash, definitely not the rad fan. > When the thing turned on this morning , i was > just standing there looking at it, > > It hadnt run since yesterday afternoon. > Hopefully you still have the "Enter Diag Mode" where you press and hold the two buttons on the ATC, then click one time to display a 0 with the stick figure. While running diags, you can go back to test select mode by turning the temp control one click in either direction which should get rid of the stick figure and any arrows. From the diags mode, turn the temp knob until the desired test is displayed in the digits. Then press A/C or RECIRC to display the value or select an output test mode by pressing again until the display blinks. Normally you read an output first, then hit that button again to run the actuator test. For number display: No arrows= 0-99 Middle [panel] arrow = 100-199 Panel + Defrost arrow = 200-299. Test: 1 blower control switch, A/D convertor. Display only 2 blower feedback display only 3 blower speed, can run an actuator test 4 blower high speed relay can run actuator test. |
Re: 97 GC - Blower comes on by itself -- with no key!!
PoBoy proclaimed:
> No the blower under the dash, definitely not the rad fan. > When the thing turned on this morning , i was > just standing there looking at it, > > It hadnt run since yesterday afternoon. > Hopefully you still have the "Enter Diag Mode" where you press and hold the two buttons on the ATC, then click one time to display a 0 with the stick figure. While running diags, you can go back to test select mode by turning the temp control one click in either direction which should get rid of the stick figure and any arrows. From the diags mode, turn the temp knob until the desired test is displayed in the digits. Then press A/C or RECIRC to display the value or select an output test mode by pressing again until the display blinks. Normally you read an output first, then hit that button again to run the actuator test. For number display: No arrows= 0-99 Middle [panel] arrow = 100-199 Panel + Defrost arrow = 200-299. Test: 1 blower control switch, A/D convertor. Display only 2 blower feedback display only 3 blower speed, can run an actuator test 4 blower high speed relay can run actuator test. |
Re: 97 GC - Blower comes on by itself -- with no key!!
Yes the 2 button diag mode entry works,
I did the first diag procedure and got 00 code, next i'll try the individual tests. james Lon wrote: > PoBoy proclaimed: > >> No the blower under the dash, definitely not the rad fan. >> When the thing turned on this morning , i was >> just standing there looking at it, >> >> It hadnt run since yesterday afternoon. >> > Hopefully you still have the "Enter Diag Mode" where you > press and hold the two buttons on the ATC, then click one > time to display a 0 with the stick figure. > > While running diags, you can go back to test select mode by > turning the temp control one click in either direction which > should get rid of the stick figure and any arrows. > > From the diags mode, turn the temp knob until the desired test > is displayed in the digits. Then press A/C or RECIRC to display > the value or select an output test mode by pressing again until > the display blinks. Normally you read an output first, then hit > that button again to run the actuator test. > > For number display: > > No arrows= 0-99 > Middle [panel] arrow = 100-199 > Panel + Defrost arrow = 200-299. > > Test: > > 1 blower control switch, A/D convertor. Display only > 2 blower feedback display only > 3 blower speed, can run an actuator test > 4 blower high speed relay can run actuator test. |
Re: 97 GC - Blower comes on by itself -- with no key!!
Yes the 2 button diag mode entry works,
I did the first diag procedure and got 00 code, next i'll try the individual tests. james Lon wrote: > PoBoy proclaimed: > >> No the blower under the dash, definitely not the rad fan. >> When the thing turned on this morning , i was >> just standing there looking at it, >> >> It hadnt run since yesterday afternoon. >> > Hopefully you still have the "Enter Diag Mode" where you > press and hold the two buttons on the ATC, then click one > time to display a 0 with the stick figure. > > While running diags, you can go back to test select mode by > turning the temp control one click in either direction which > should get rid of the stick figure and any arrows. > > From the diags mode, turn the temp knob until the desired test > is displayed in the digits. Then press A/C or RECIRC to display > the value or select an output test mode by pressing again until > the display blinks. Normally you read an output first, then hit > that button again to run the actuator test. > > For number display: > > No arrows= 0-99 > Middle [panel] arrow = 100-199 > Panel + Defrost arrow = 200-299. > > Test: > > 1 blower control switch, A/D convertor. Display only > 2 blower feedback display only > 3 blower speed, can run an actuator test > 4 blower high speed relay can run actuator test. |
Re: 97 GC - Blower comes on by itself -- with no key!!
Yes the 2 button diag mode entry works,
I did the first diag procedure and got 00 code, next i'll try the individual tests. james Lon wrote: > PoBoy proclaimed: > >> No the blower under the dash, definitely not the rad fan. >> When the thing turned on this morning , i was >> just standing there looking at it, >> >> It hadnt run since yesterday afternoon. >> > Hopefully you still have the "Enter Diag Mode" where you > press and hold the two buttons on the ATC, then click one > time to display a 0 with the stick figure. > > While running diags, you can go back to test select mode by > turning the temp control one click in either direction which > should get rid of the stick figure and any arrows. > > From the diags mode, turn the temp knob until the desired test > is displayed in the digits. Then press A/C or RECIRC to display > the value or select an output test mode by pressing again until > the display blinks. Normally you read an output first, then hit > that button again to run the actuator test. > > For number display: > > No arrows= 0-99 > Middle [panel] arrow = 100-199 > Panel + Defrost arrow = 200-299. > > Test: > > 1 blower control switch, A/D convertor. Display only > 2 blower feedback display only > 3 blower speed, can run an actuator test > 4 blower high speed relay can run actuator test. |
Re: 97 GC - Blower comes on by itself -- with no key!!
PoBoy proclaimed:
> Yes the 2 button diag mode entry works, > I did the first diag procedure and got 00 code, > next i'll try the individual tests. > You might wish to cough up for the Factory Service Manual and Body Diagnostic Manual from www.techauthority.com. Much of the stuff presumes you have a scan tool, but the rest comes in handy even if just so you can perform some of the road tests before having a chat with your mechanic. |
Re: 97 GC - Blower comes on by itself -- with no key!!
PoBoy proclaimed:
> Yes the 2 button diag mode entry works, > I did the first diag procedure and got 00 code, > next i'll try the individual tests. > You might wish to cough up for the Factory Service Manual and Body Diagnostic Manual from www.techauthority.com. Much of the stuff presumes you have a scan tool, but the rest comes in handy even if just so you can perform some of the road tests before having a chat with your mechanic. |
Re: 97 GC - Blower comes on by itself -- with no key!!
PoBoy proclaimed:
> Yes the 2 button diag mode entry works, > I did the first diag procedure and got 00 code, > next i'll try the individual tests. > You might wish to cough up for the Factory Service Manual and Body Diagnostic Manual from www.techauthority.com. Much of the stuff presumes you have a scan tool, but the rest comes in handy even if just so you can perform some of the road tests before having a chat with your mechanic. |
Re: 97 GC - Blower comes on by itself -- with no key!!
The factory service manual is easy to find, but did you get the
'Body Diagnostic Manual' from them too? I couldnt seem to pull it up. thx, jt Lon wrote: > PoBoy proclaimed: > >> Yes the 2 button diag mode entry works, >> I did the first diag procedure and got 00 code, >> next i'll try the individual tests. >> > You might wish to cough up for the Factory Service Manual and Body > Diagnostic Manual from www.techauthority.com. Much of the stuff > presumes you have a scan tool, but the rest comes in handy even if > just so you can perform some of the road tests before having a > chat with your mechanic. |
Re: 97 GC - Blower comes on by itself -- with no key!!
The factory service manual is easy to find, but did you get the
'Body Diagnostic Manual' from them too? I couldnt seem to pull it up. thx, jt Lon wrote: > PoBoy proclaimed: > >> Yes the 2 button diag mode entry works, >> I did the first diag procedure and got 00 code, >> next i'll try the individual tests. >> > You might wish to cough up for the Factory Service Manual and Body > Diagnostic Manual from www.techauthority.com. Much of the stuff > presumes you have a scan tool, but the rest comes in handy even if > just so you can perform some of the road tests before having a > chat with your mechanic. |
All times are GMT -4. The time now is 06:54 PM. |
© 2024 MH Sub I, LLC dba Internet Brands